text.skipToContent text.skipToNavigation

Call us at 1-888-826-6342

Call us at 1-888-826-6342

Metric, Low Profile, Tension & Compression Load Cells

10,000 kgf, ±0.1%, Linearity, 3 mV/V Output, Cable

$1,509.25

Item# LCM402-10K

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 $1,509.25
10-24 $1,433.79
25-49 $1,403.60
50-99 $1,343.23
100+ $1,313.05

Please contact Technical Sales Team for assistance. Any remaining stock is available for purchase

Only 1 left

Limited Stock
10,000 kgf, ±0.1%, Linearity, 3 mV/V Output, Cable LCM402-10K LCM402-10K
  • All Stainless Steel for Harsh Industrial Applications
  • 5-Point NIST Traceable Calibration with 59 KOhm Shunt Cal Data Provided
  • 0.25% Interchangeable for Multiple Load Cell Applications
  • Rugged Industrail Design
  • Easy to Use Twist Lock Connection

LCM402-10K Model Options

View all models

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Connection Type
Cable Length
Weight Capacity
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
OD
Through hole (ID)/ Threaded hole dimension
Height


  • Hysteresis 0.10% FSO
  • Input Resistance 350 ±10 Ω
  • Linearity 0.10% FSO
  • Load Cell Material 17-4 PH stainless steel
  • Maximum Ambient Temperature LC402: 107°C (225°F)
  • Maximum Compensation Temperature 71 {C} (160 {F})
  • Measurement Type Load
  • Minimum Compensation Temperature 16 {C} (60 {F})
  • Repeatability 0.05% FSO
  • Output Voltage 3 mV/V ±0.25%
  • Safe Overload 150% of Capacity
  • Ultimate Overload 300% of Capacity
  • Temperature Effects 0.0045% FSO/°C
  • Zero Balance ±1% FSO
  • Style Tension/Compression
The LCM402 and LCM412 are also available in standard configurations, with 0-50 to 0-750,000 lb ranges and standard threads. Please see the LC402 for complete details, or contact our Pressure department for more information..


SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ±0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ±1% FSO
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
   Zero: 0.0025% FSO/°F
   Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
   ranges ?400,000 lb: 300% of Capacity
    ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ±10 ?
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
   LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
   LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately
loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA

Can load be applied over the entire face of the load cell or is there a certain area on the face that must receive load?

Asked by: willmar
Thank you for your inquiry. That load cell should be loaded only on the inner raised lip or with a load button installed Hope this was helpful?
Answered by: application engineer je
Date published: 2019-11-15

how is the load cell mounted? are the holes on the outer edge used to mount to a surface or can a rod be connected on the UNF thread from both ends, in order to allow for push or pull? are there any mounting instructions you can provide?

Asked by: crudevic
The outer holes are used surface mount the load. The load in then applied via the center threaded hole. the only way use the load for in line load measurement is to bolt it to a tension plate using the mounting holes. You can the thread a rod ends into the load cell and into the tension plate. Information on the tension plate is shown on the pdf datasheet for the LC402 load cell
Answered by: Applications Engineer JK
Date published: 2022-06-17

Does this load cell measure Fx, Fy, Fz, Mx, My, Mz or does it only measure one value?

Asked by: emilionhalliford
Hi, thanks for contacting Omega. This is a single output load cell, only providing tension or compression signals perpendicular to the planner faces. Please contact our Tech Support if you need any further assistance.
Answered by: Jane
Date published: 2019-01-29
  • y_2023, m_1, d_10, h_22CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.34
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_LCM402-10K, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
100 kgf, M10x1.5 threads
$186.35
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
10000 kgf, M24x2 threads
$457.69
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
5000 kgf, M20x1.5 threads
$204.21
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
1500 kgf, M12x1.75 threads
$211.97
2 In Stock
Accessories
Mating Connector for LCM115 Series
$38.45
0 In Stock
en-US
en
Save Configuration