0.25% Accuracy Marine Pressure Transducers All Stainless Steel Construction
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination |
---|---|---|---|---|---|---|---|---|---|
|
0 to 5 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Female
|
MIL-26482-I 10-6P
|
|
0 to 20 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Female
|
MIL-26482-I 10-6P
|
|
0 to 50 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Female
|
MIL-26482-I 10-6P
|
|
0 to 100 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Female
|
MIL-26482-I 10-6P
|
|
0 to 150 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/4"
|
NPT Female
|
MIL-26482-I 10-6P
|
The PX275 series are OEM style on panel mount chassis with barbed fittings, with up to 6 field selectable ranges as low as 0.1 inH20 and a 4-20 mA output.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 30 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 0.1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
Selectable
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
The PX276 is a duct pressure transducer and static, 8" pressure probe integrated as one unit with to 3 field selectable ranges with a 4-20 output in ranges 0-0.1 to 0-30 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5 inH2O
|
Gauge
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
8 in Wand
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 15 inH2O
|
Gauge
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
8 in Wand
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
The PX2310 series is suitable for energy management, process control, liquid level systems, etc. with 4 selectable outputs for ranges from 0-50 to 0-200 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 50 psi
|
Differential
|
> 0.25%
|
±1%
|
Selectable
|
Selectable
|
1/8"
|
NPT Female
|
Conduit
|
-20 to 85 °C (-4 to 185 °F)
|
Rangeable
|
|
0 to 100 psi
|
Differential
|
> 0.25%
|
±1%
|
Selectable
|
Selectable
|
1/8"
|
NPT Female
|
Conduit
|
-20 to 85 °C (-4 to 185 °F)
|
Rangeable
|
|
0 to 250 psi
|
Differential
|
> 0.25%
|
±1%
|
Selectable
|
Selectable
|
1/8"
|
NPT Female
|
Conduit
|
-20 to 85 °C (-4 to 185 °F)
|
Rangeable
|
The PXM509-IS metric series is FM approved, shock and vibration rated, with a ±0.08% accuracy, ideal for hazardous locations. Available in ranges from 25 mbar to 350 bar.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 bar
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Male
|
Cable
|
Not Applicable
|
|
0 to 1 bar
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Male
|
Cable
|
Not Applicable
|
|
0 to 1 bar
|
Vacuum
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Male
|
Cable
|
Not Applicable
|
|
0 to 2 bar
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Male
|
Cable
|
Not Applicable
|
|
0 to 2 bar
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Male
|
Cable
|
Not Applicable
|
PX78 series submersible transducers are watertight, suited to most underwater applications and have current and ratiometric output options.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value (compensated range) | Output Signal | Electrical Output | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 10 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-29 to 93 °C (-20 to 200 °F)
|
Not Applicable
|
This series captures transient events at a high sample rate when the events are erratically spread over a large period of time, triggered by programmed thresholds.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 300 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Digital
|
Data
|
1/2x1/4"
|
NPT MxF
|
-40 to 80 °C (-40 to 176 °F)
|
Battery Powered
|
|
0 to 300 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Digital
|
Data
|
1/4"
|
NPT Male
|
-40 to 80 °C (-40 to 176 °F)
|
Battery Powered
|
|
0 to 500 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Digital
|
Data
|
1/4"
|
NPT Male
|
-40 to 80 °C (-40 to 176 °F)
|
Battery Powered
|
The PX920 series has titanium wetted parts for media compatibility and SOS construction is durable with excellent stability over a wide temperature range.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 100 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Male
|
Internal Terminal Strip
|
-20 to 85 °C (-4 to 185 °F)
|
|
0 to 150 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Male
|
Internal Terminal Strip
|
-20 to 85 °C (-4 to 185 °F)
|
|
0 to 15,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Male
|
Internal Terminal Strip
|
-20 to 85 °C (-4 to 185 °F)
|
|
0 to 200 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Male
|
Internal Terminal Strip
|
-20 to 85 °C (-4 to 185 °F)
|
|
0 to 300 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Male
|
Internal Terminal Strip
|
-20 to 85 °C (-4 to 185 °F)
|
The PX265 series have a rugged, seamless, NEMA 4 enclosure and 3 field selectable ranges with a 0-5 or 0-10 volt output. Available in ranges from 0-100 to 0-500 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 100 psi
|
Gauge
|
> 0.25%
|
±1%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
NPT Female
|
Terminal Block
|
-18 to 82 °C (0 to 180 °F)
|
|
0 to 300 psi
|
Gauge
|
> 0.25%
|
±1%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
NPT Female
|
Terminal Block
|
-18 to 82 °C (0 to 180 °F)
|
The PX480 series are compact and rugged with vacuum, absolute, and gauge pressure, current and voltage outputs to integrate with a variety of industrial and OEM applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 6 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 30 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
-15 to 60 psi
|
Compound Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 60 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Voltage
|
1 to 5 Vdc
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
The PX5500 series are stable to 0.1% of FSO over an 18-month period and have 100,000 hrs MTBF rate to withstand aerospace and demanding applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 15 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 50 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
The PX180 series are compact and rugged with vacuum, absolute, and gauge pressure, current and voltage outputs to integrate with a variety of industrial and OEM applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 6 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 100 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 200 psi
|
Gauge
|
> 0.25%
|
±0.3%
|
Ratiometric mV/V
|
10 mV/V
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Gauge
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
|
0 to 6 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Male
|
Cable
|
-40 to 80 °C (-40 to 176 °F)
|
Not Applicable
|
The PX1005 series is designed for cryogenic service at temperatures from -196 to +149°C (-320 to +300°F) while remaining at a high 0.1% Stability for 18 months.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-196 to 149 °C (-321 to 300 °F)
|
Not Applicable
|
|
0 to 50 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-196 to 149 °C (-321 to 300 °F)
|
Not Applicable
|
|
0 to 100 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-196 to 149 °C (-321 to 300 °F)
|
Not Applicable
|
|
0 to 250 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-196 to 149 °C (-321 to 300 °F)
|
Not Applicable
|
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 50 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-10 to 60 °C (14 to 140 °F)
|
Not Applicable
|
|
0 to 150 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-10 to 60 °C (14 to 140 °F)
|
Not Applicable
|
The PX305 series are general purpose transmitters with a 4-20 output. Limited pressure ranges in stock.
Product Number | Pressure Range Unit | Pressure Range Min | Pressure Range Max | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
psi
|
0
|
1000
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
|
psi
|
0
|
3000
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Mini DIN 43650 C
|
Subminiature Millivolt Output Type Pressure Transducer for Accurate Measurements in Restricted Locations
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
7/16"
|
UNF Male
|
MIL-26482-I 10-6P
|
-54 to 121 °C (-65 to 250 °F)
|
PX709 series submersible transducers are watertight, suited to most underwater applications and have current, voltage, and ratiometric output options.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 15 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-18 to 79 °C (0 to 175 °F)
|
Not Applicable
|
|
0 to 100 psi
|
Absolute
|
0.1% to 0.25%
|
±0.2%
|
Ratiometric mV/V
|
10 mV/V
|
Submersible
|
Submersible Cable
|
-18 to 79 °C (0 to 175 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable with Conduit
|
-18 to 79 °C (0 to 175 °F)
|
Not Applicable
|
The PX80 series can measure low differential pressures even at high line pressures, up to 5,000 psi with current, voltage, and ratiometric output options.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 14 bar
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Female
|
Cable
|
-46 to 107 °C (-50 to 225 °F)
|
Not Applicable
|
|
0 to 20 bar
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Female
|
Cable
|
-46 to 107 °C (-50 to 225 °F)
|
Not Applicable
|
|
0 to 35 bar
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Female
|
Cable
|
-46 to 107 °C (-50 to 225 °F)
|
Not Applicable
|
|
0 to 50 bar
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Female
|
Cable
|
-46 to 107 °C (-50 to 225 °F)
|
Not Applicable
|
The PX35 series is temperature compensated with a hermetically sealed, stainless steel construction that is suitable for harsh environments with fluctuating temperatures.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 50 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-73 to 149 °C (-100 to 300 °F)
|
Not Applicable
|
|
0 to 40 bar
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
BSPP Female
|
MIL-26482-I 10-6P
|
-73 to 149°C (-100 to 300 °F)
|
Not Applicable
|
|
0 to 2.5 bar
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
BSPP Female
|
Cable
|
-73 to 149°C (-100 to 300 °F)
|
Not Applicable
|
|
0 to 1.6 bar
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
BSPP Female
|
MIL-26482-I 10-6P
|
Not Applicable
|
|
|
0 to 2.5 bar
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
BSPP Female
|
MIL-26482-I 10-6P
|
-73 to 149°C (-100 to 300 °F)
|
Not Applicable
|
The PX154 series are well suited to low pressure HVAC and pneumatic systems, with a NEMA 4 enclosure. Available with a 4-20 mA output in ranges from 0 -1 inH2O to 0-25 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±0.75%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Conduit
|
0 to 50 °C (32 to 122 °F)
|
|
0 to 25 inH2O
|
Differential
|
> 0.25%
|
±0.75%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Conduit
|
0 to 50 °C (32 to 122 °F)
|