The PX165 series measures differential pressure in low and ultra low ranges, down to 0.25 inches of water. Their compact size is also ideal for board mounted applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-1 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
-2 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
-5 to 5 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
The PX26 series are board mountable sensors that allow water and many other liquids to be applied to both sides in pressures in an easily mountable 4-pin package.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
-1 to 1 psi
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
10 mV/V
|
5mm
|
Tube
|
Pins
|
-40 to 85 °C (-40 to 185 °F)
|
|
0 to 1 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
1.67 mV/V
|
5mm
|
Tube
|
Pins
|
-40 to 85 °C (-40 to 185 °F)
|
|
0 to 5 psi
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
10 mV/V
|
5mm
|
Tube
|
Pins
|
-40 to 85 °C (-40 to 185 °F)
|
|
0 to 5 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
5 mV/V
|
5mm
|
Tube
|
Pins
|
-40 to 85 °C (-40 to 185 °F)
|
|
-15 to 15 psi
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
10 mV/V
|
5mm
|
Tube
|
Pins
|
-40 to 85 °C (-40 to 185 °F)
|
The PX2650 series is an economical solution to measure dry gasses in building management, HVAC, or clean rooms with a voltage output in low ranges from ± 0.25 to ±50 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
0 to 10 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
-1 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
0 to 25 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
-2 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
The PX5500 series are stable to 0.1% of FSO over an 18-month period and have 10-year MTBF rate to withstand rigorous testing and demanding applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
MIL-26482-I 10-6P
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
The PX51 series are heavy duty, all stainless steel pressure transducers for harsh environments and pressure ranges up to 30,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
The PX1004 and PX1009 series can withstand high operating temperatures up to 232°C (450°F) and 343°C (650°F) respectively, with low thermal drift 1%/100 °F.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
AS5205/MS33656-4
|
MIL-26482-I 10-6P
|
-54 to 232 °C (-65 to 450 °F)
|
Not Applicable
|
The PX600 series are Omega's smallest transducers, but are still rugged and accurate for industrial environments. Available in ranges from 200 to 10,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 10000 psi
|
Gauge
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
2 mV/V
|
3/8"
|
Flush
|
Cable
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
The PX91 series withstand temperatures up to 218°C(425°F) and are available in pressure ranges up to 200,000 psi. Designed for use in high temperature test chambers.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
1 mV/V
|
1/2"
|
High Pressure NPSM
|
Cable
|
-56 to 204 °C (-70 to 400 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Sealed Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
1 mV/V
|
1/2"
|
High Pressure NPSM
|
Cable
|
-56 to 204 °C (-70 to 400 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
Conduit
|
-46 to 121 °C (-50 to 250 °F)
|
Lightening Protected Amplifier Box
|
The PX274 series have a rugged, seamless, NEMA 4 enclosure and 6 field selectable ranges with a 4-20 mA output. Available in ranges from 0-0.1 to 0-30 in H2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 30 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 0.1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Current
|
4 to 20 mA
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
Rangable
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
Selectable
|
3/16"
|
Barbed Fitting
|
Terminal Block
|
-18 to 80 °C (0 to 176 °F)
|
N/A
|
The PX654 series are well suited for use in clean rooms, HVAC systems, and laboratory fume hoods. They have a 4-20 mA or 1-5 V output in ranges from ± 0.05 to +± 100 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 2 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 3 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 5 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
The PX2760 is an electric barometer with a rugged capacitive design, fast response time, and 3 field selectable ranges in one unit.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 20 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
|
600 to 1,060 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
|
800 to 1,100 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
The PX880 series is FM and CSA approved for hazardous industrial locations and ideal for use with corrosive media and in hazardous environments. Available from 15 to 3,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 15 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 30 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
The PX02 series has an accessible shunt resistor for quick, convenient calibration checks along with a hermetically sealed double diaphragm for harsh environments.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
16 to 32 inHg
|
Barometric
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
26 to 32 inHg
|
Barometric
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
28 to 32 inHg
|
Barometric
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
The PX103 series has a fully flush diaphragm without any threads, making it ideal for hard-to-measure fluids. Available in both amplified voltage and 4 to 20mA outputs.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Flush
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Flush
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Flush
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Flush
|
Cable
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Flush
|
MIL-26482-I 10-6P
|
-45 to 121 °C (-49 to 250 °F)
|
Not Applicable
|
The PX51-IS series is FM approved with a sealed stainless steel case for harsh and hazardous environments. Available in gauge and absolute ranges from 10 to 30,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 75 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 75 °C (-40 to 167 °F)
|
Intrinsically Safe IS FM Approval
|
|
0 to 100 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 75 °C (-40 to 167 °F)
|
Intrinsically Safe IS FM Approval
|
|
0 to 200 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 75 °C (-40 to 167 °F)
|
Intrinsically Safe IS FM Approval
|
|
0 to 15,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
High Pressure F-250-C
|
Mini DIN 43650 C
|
-40 to 75 °C (-40 to 167 °F)
|
Intrinsically Safe IS FM Approval
|
|
0 to 1500 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Intrinsically Safe IS FM Approval
|
The PX4600 series are small, lightweight, packaged for board mounting in OEM and aerospace applications to withstand high shock and vibration.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 15 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
3/16"
|
Tube
|
T-08
|
-55 to 150 °C (-67 to 300 °F)
|
|
0 to 15 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
3/16"
|
Tube
|
T-08
|
-55 to 150 °C (-67 to 300 °F)
|
|
0 to 20 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
3/16"
|
Tube
|
T-08
|
-55 to 150 °C (-67 to 300 °F)
|
|
0 to 20 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
3/16"
|
Tube
|
T-08
|
-55 to 150 °C (-67 to 300 °F)
|
|
0 to 25 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Ratiometric mV/V
|
3 mV/V
|
3/16"
|
Tube
|
T-08
|
-55 to 150 °C (-67 to 300 °F)
|
The PX663 series features a compact, space saving DIN rail mountable design in low differential pressure ranges with onboard voltage regulations.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-29 to 82 °C (-20 to 180 °F)
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-29 to 82 °C (-20 to 180 °F)
|
|
0 to 3 inH2O
|
Differential
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-29 to 82 °C (-20 to 180 °F)
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
Terminal Block
|
-29 to 82 °C (-20 to 180 °F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.5%
|
Voltage
|
1 to 5 Vdc
|
1/8"
|
NPT Female
|
Terminal Block
|
-29 to 82 °C (-20 to 180 °F)
|
The PX41-MSHA series is designed for mine safety applications with a rugged, sealed, stainless steel construction and versatile current or voltage outputs.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 50 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/2x1/4"
|
NPT MxF
|
Cable
|
Not Applicable
|
Not Applicable
|
|
0 to 50 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/2x1/4"
|
NPT MxF
|
Cable
|
Not Applicable
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/2x1/4"
|
NPT MxF
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Mine Safety and Health Admin
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/2x1/4"
|
NPT MxF
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Mine Safety and Health Admin
|
|
0 to 75 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
High Performance Pressure Transducer Long Term Reliability Aerospace Quality
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 25 psi
|
Absolute
|
< 0.1%
|
±0.1%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
5ft Cable
|
The PC2780 is a high ±0.25 accuracy that makes it ideal for environmental, weather, laboratory, and test station monitoring and data logging.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
500 to 1,100 mbar
|
Barometric
|
> 0.25%
|
±0.5%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-40 to 60 °C (-40 to 140 °F)
|
|
600 to 1,100 mbar
|
Barometric
|
> 0.25%
|
±0.4%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-40 to 60 °C (-40 to 140 °F)
|
|
800 to 1,100 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-40 to 60 °C (-40 to 140 °F)
|
|
600 to 1,060 mbar
|
Barometric
|
> 0.25%
|
±0.4%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-40 to 60 °C (-40 to 140 °F)
|
|
800 to 1,060 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0 to 5 Vdc
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-40 to 60 °C (-40 to 140 °F)
|