Alta Long Range Wireless Control unit with 2 Relays

Monnit Alta Wireless Control

$289.00

Item# MNO2-9-CTL-10

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $289.00
5-9 $274.55
10-24 $268.77
25-49 $257.21
50-99 $251.43
100+ $245.65

In stock

Lead Time (If not in stock): 5 weeks
Monnit Alta Wireless Control MNO2-9-CTL-10 MNO2-9-CTL-10
  • Allows for Automated Control
  • 10 Amp or 30 Amp Models Available
  • Two Separate Relays per Unit
  • Can be Triggered by Sensor Notification to Activate at Set Conditions
  • Can be Triggered Manually Via Online Monitoring Interface
  • A/C Powered, Always on for Immediate Response from Paired Sensors

MNO2-9-CTL-10 Model Options

View all models

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Actuator(s)
Function
Radio Frequency Compatibility
Supply Power
Additional Features


Monnit Alta wireless control units contain two separate relay switches allowing for individual control through the iMonnit online sensors portal. The control unit relays can be switched on/off manually through the software or automatically by any wireless sensor notification assigned to a single sensor or group of sensors when a specified condition is detected.

The dual relays can be programmed separately to turn off or on wirelessly based on different sensor conditions. They can be used for on-off control of devices such as heaters, pumps, solenoid valves, etc. In an example application, two fluid tanks with blanket heaters need to be maintained at different temperatures for feeding a mixing process. One relay is programmed to turn on when the wireless temperature sensor in one tank reports a temperature below 90C and turn off when that sensor reports a temperature of 95C. The other relay is programmed the same way to maintain the second tank at a temperature between 60C and 65C.
loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Related Categories

en-US
en
Save Configuration